Wind Stopping 16 (WMH)
The larger of the two Wind Stopping series from our heavy industrial range, the WMH units provide AMCA certification and feature 5-7 horsepower motors, which can repel wind gusts up to 15MPH at heights up to 16 ft. high. Standard color for these industrial models is Titanium Silver and heated options are available.
Have a question?
Contact Us
MODEL NUMBER | WIDTH OF DOOR | DOOR HEIGHT | FLA (AMPACITY) THREE PHASE | SOUND dBA | WEIGHT (lbs) | ||
208V/230V | 460V | 575V | |||||
WMH96 | 96" | 16' - 20' | 38.0 / 31.6 | 15.8 | 12.6 | 69 | 635 |
WMH120 | 120" | 16' - 20' | 38.0 / 31.6 | 15.8 | 12.6 | 69 | 735 |
WMH 144 | 144" | 16' - 20' | --- / 42.0 | 21.0 | 16.8 | 69 | 890 |
WMH168 | 168" | 16' - 20' | 57.0 / 47.4 | 23.7 | 18.9 | 70 | 1060 |
WMH 192 | 192" | 16' - 20' | 76.0 / 63.2 | 31.6 | 25.2 | 72 | 1275 |
DOOR SWITCHES
Automatic on/off control of air curtain as door is opened and closed
Line Voltage
- 99-014 Door Limit Switch Combination roller and plunger · 20 amps, 250v, or 1 hp max.
24-Volt Control
- 99-124 Industrial Floor-Mounted Magnetic Reed Switch Only Floor-mounted · NOTE: Control panel required
- 99-125 Industrial Surface-Mounted Magnetic Reed Switch Only Surface-mounted · NOTE: Control panel required
CONTROL PACKAGES
Combination packages of door switches, controllers, time delays, and thermostats
Line Voltage
- 99-063 Analog Thermostat - Remote-mounted
- 99-064 Analog Thermostat DPST - Double pole, single throw · Acts as heat on demand · Remote-mounted
24-Volt Control
- J0034 Door Limit Switch with Adjustable Time Delay, 1 sec. – 17 min. · Surface-mounted · NOTE: Control panel required
- J0039 Industrial Magnetic Reed Switch with Adjustable Time Delay · 115v, 1 sec. – 17 min. · Floor-mounted · NOTE: Control panel required
- J0040 Industrial Magnetic Reed Switch with Adjustable Time Delay, 1 sec. – 17 min. · Surface-mounted · NOTE: Control panel required
FILTERS
- WMHFILTER-[size] Please consult factory for selection of V-bank filters
MOTOR CONTROL PANELS
Remote-mounted control panels for all 3Φ units and 1Φ units when greater than 1 hp (NEMA 1) · Units come standard with HOA (hand/off/auto) switch · Panel shipped loose · Standard color Battleship Gray [vc] Voltage codes: A = 115/1/60 D = 208-230/1/60 G = 208-230/3/60 H = 460/3/60 [fc] Furnace quantity code: #F (for example, 1F = 1 furnace, 2F = 2 furnaces, etc.)
- MCPE-1U 1-Motor Control Panel 5 hp · Unheated
- MCPE-2U 2-Motor Control Panel 5 hp · Unheated
- MCPE-3U 3-Motor Control Panel 5 hp · Unheated
- MCPE-4U 4-Motor Control Panel 5 hp · Unheated
- MCPF-1U 1-Motor Control Panel 7 hp · Unheated
- MCPF-2U 2-Motor Control Panel 7 hp · Unheated
- MCPE-1V 1-Motor Control Panel 5 hp · Steam/ Hot Water Heated
- MCPE-2V 2-Motor Control Panel 5 hp · Steam/ Hot Water Heated
- MCPE-3V 3-Motor Control Panel 5 hp · Steam/ Hot Water Heated
- MCPE-4V 4-Motor Control Panel 5 hp · Steam/ Hot Water Heated
- MCPF-1V 1-Motor Control Panel 7 hp · Steam/ Hot Water Heated
- MCPF-2V 2-Motor Control Panel 7 hp · Steam/ Hot Water Heated
- MCPE-1I [vc]-[fc] 1-Motor Control Panel 5 hp · Indirect Gas Fired Heated - Specify codes for [vc]: required voltage [fc]: furnace quantity
- MCPE-2I [vc]-[fc] 2-Motor Control Panel 5 hp · Indirect Gas Fired Heated - Specify codes for [vc]: required voltage [fc]: furnace quantity
- MCPE-3I [vc]-[fc] 3-Motor Control Panel 5 hp · Indirect Gas Fired Heated - Specify codes for [vc]: required voltage [fc]: furnace quantity
- MCPE-4I [vc]-[fc] 4-Motor Control Panel 5 hp · Indirect Gas Fired Heated - Specify codes for [vc]: required voltage [fc]: furnace quantity
- MCPF-1I [vc]-[fc] 1-Motor Control Panel 7 hp · Indirect Gas Fired Heated - Specify codes for [vc]: required voltage [fc]: furnace quantity
- MCPF-2I [vc]-[fc] 2-Motor Control Panel 7 hp · Indirect Gas Fired Heated - Specify codes for [vc]: required voltage [fc]: furnace quantity
PANEL ADD-ONS
- 94-013 Adjustable Time Delay, 1 sec. - 17 min. · NOTE: Control panel required
- 99-165 Non-fused disconnect · 32 amps, Panel-mounted
- 99-164 Non-fused disconnect · 63 amps, Panel-mounted
- 99-114 Fused disconnect · 32 amps, Panel-mounted
- 99-115 Fused disconnect · 63 amps, Panel-mounted
- MCP-MTD Factory-Mounted Motor Control Panel