Wind Stopping 14 (WMI)

Wind Stopping 14 (WMI)

The smaller of the two Wind Stopping series from our heavy industrial range, the WMI units provide AMCA certification and feature either 2-3 horsepower motors, which can repel wind gusts up to 20MPH at heights up to 14 ft. high. Standard color for these industrial models is Titanium Silver and heated options are available.

Have a question?
Contact Us

Are you a consultant?

18-month warranty
22" Profile
Certifications
Corrosion Resistant Powder Coated Finish
Direct Drive Unit
Direct-drive motor
Durable Metal Construction
Durable metal design
Easy To Install
Environmental Protection: 16’
Flying-insects Protection: 14’
Freight not included
Heavy duty motors
Low Maintenance
Made in USA
Standard color: Titanium Silver
Wind-Stopping Protection: 14’
MODEL NUMBER WIDTH OF DOOR DOOR HEIGHT FLA (AMPACITY) THREE PHASE SOUND dBA WEIGHT (lbs)
208V/230V 460V 575V
WMI96 96" 14' - 18' 14.4 / 14.0 7.0 4.6 66 515
WMI120 120" 14' - 18' 28.4 / 21.2 10.6 4.6 66 610
WMI144 144" 14' - 18' 28.4 / 21.2 10.6 4.6 66 695
WMI168 168" 14' - 18' 42.6 / 31.8 15.9 6.9 68 880
WMI192 192" 14' - 18' 28.8 / 28.0 14.0 9.2 68 1030

 

DOOR SWITCHES

Automatic on/off control of air curtain as door is opened and closed

 

Line Voltage

- 99-014  Door Limit Switch Combination roller and plunger · 20 amps, 250v, or 1 hp max.

 

24-Volt Control

- 99-124  Industrial Floor-Mounted Magnetic Reed Switch Only - Floor-mounted · NOTE: Control panel required
- 99-125  Industrial Surface-Mounted Magnetic Reed Switch Only - Surface-mounted · NOTE: Control panel required

 

 

CONTROL PACKAGES

Combination packages of door switches, controllers, time delays, and thermostats 

 

Line Voltage

- 99-063  Analog Thermostat - Remote-mounted 
- 99-064  Analog Thermostat DPST - Double pole, single throw · Acts as heat on demand · Remote-mounted

 

24-Volt Control

- J0034   Door Limit Switch with Adjustable Time Delay, 1 sec. – 17 min. · Surface-mounted · NOTE: Control panel required
- J0039   Industrial Magnetic Reed Switch with Adjustable Time Delay · 115v, 1 sec. – 17 min. · Floor-mounted · NOTE: Control panel required
- J0040   Industrial Magnetic Reed Switch with Adjustable Time Delay, 1 sec. – 17 min. · Surface-mounted · NOTE: Control panel required

 

 

FILTERS

 

- WMIFILTER-[size]  Please consult factory for selection of V-bank filters

 

 

MOTOR CONTROL PANELS

Remote-mounted control panels for all 3Φ units and 1Φ units when greater than 1 hp (NEMA 1) · Units come standard with HOA (hand/off/auto) switch · Panel shipped loose · Standard color Battleship Gray · NOTE: Electric heated units include internal control panel and remote-mounted 24v thermostat with heat/off/fan only switch [vc] Voltage codes: A = 115/1/60 D = 208-230/1/60 G = 208-230/3/60 H = 460/3/60 - [fc] Furnace quantity code: #F (for example, 1F = 1 furnace, 2F = 2 furnaces, etc.)

[vc] Voltage codes: A = 115/1/60 D = 208-230/1/60 G = 208-230/3/60 H = 460/3/60

[fc] Furnace quantity code: #F (for example, 1F = 1 furnace, 2F = 2 furnaces, etc.)

 

- MCPD-1U 1-Motor Control Panel 3 hp · Unheated
- MCPD-2U 2-Motor Control Panel 3 hp · Unheated
- MCPD-3U 3-Motor Control Panel 3 hp · Unheated
- MCPD-1V 1-Motor Control Panel 3 hp · Steam/ Hot Water Heated
- MCPD-2V 2-Motor Control Panel 3 hp · Steam/ Hot Water Heated
- MCPD-3V 3-Motor Control Panel 3 hp · Steam/ Hot Water Heated
- MCPD-2I [vc]-[fc]  2-Motor Control Panel 3 hp · Indirect Gas Fired Heated - Specify codes for [vc]: required voltage, [fc]: furnace quantity
- MCPD-3I [vc]-[fc]  3-Motor Control Panel 3 hp · Indirect Gas Fired Heated - Specify codes for [vc]: required voltage, [fc]: furnace quantity
- MCPC-1U 1-Motor Control Panel 2 hp · Unheated
- MCPC-2U 2-Motor Control Panel 2 hp · Unheated
- MCPC-4U 4-Motor Control Panel 2 hp · Unheated
- MCPC-1V   1-Motor Control Panel 2 hp · Steam/ Hot Water Heated
- MCPC-2V   2-Motor Control Panel 2 hp · Steam/ Hot Water Heated
- MCPC-4V   4-Motor Control Panel 2 hp · Steam/ Hot Water Heated
- MCPC-2I [vc]-[fc]  2-Motor Control Panel 3 hp · Indirect Gas Fired Heated - Specify codes for [vc]: required voltage [fc]: furnace quantity 
- MCPC-4I [vc]-[fc]  4-Motor Control Panel 3 hp · Indirect Gas Fired Heated - Specify codes for [vc]: required voltage [fc]: furnace quantity 

 

 

PANEL ADD-ONS

- 94-013  Adjustable Time Delay, 1 sec. - 17 min. · NOTE: Control panel required
- 99-165  Non-fused disconnect · 32 amps - Panel-mounted
- 99-164  Non-fused disconnect · 63 amps - Panel-mounted
- 99-114  Fused disconnect · 32 amps - Panel-mounted 
- 99-115  Fused disconnect · 63 amps - Panel-mounted 
- MCP-MTD Factory-Mounted Motor Control Panel

Industry Application: 
HVAC & Mechanical
Loading Dock
Docks & Doors
Loading Dock
Shipping & Receiving
Airplane Hangar
Internal Plant Separation
Specialty Industries
Pest Control
Electrical
Government/Military
Specialty Applications: 
Wash Down
Indirect Gas
Prison Package (Tamper Proof)
Vertical Mount
Other Uses: 
Transportation Terminals
Internal Plant Separation
Loading Dock