Phantom 10 (PH10)
Mars Phantom 10' Series is designed for door heights of 10'
The Phantom Series is the choice for architects and designers who need all the performance and protection of a Mars Air Curtain, but need the unit to blend in with the building's internal or external aesthetics. Our Phantom units feature the same top-performing internal components as our 1/2 HP Standard Units, but are enclosed in housing which can be concealed and recess-mounted into a ceiling. The units are quieter and less conspicuous, without sacrificing anything in their ability to do the job required. Standard color for the Phantom Models is Pearl White and heated options are available.
Have a question?
Contact Us
MODEL NUMBER | WIDTH OF DOOR | DOOR HEIGHT | FLA (AMPACITY) SINGLE PHASE | FLA (AMPACITY) THREE PHASE | SOUND dBA | WEIGHT (lbs) | |||
115V | 208V/230V | 208V/230V | 460V | 575V | |||||
PH1036 | 36" | 10' | 5.1 | 2.5 / 2.5 | 1.8 / 1.6 | 0.8 | 0.7 | 66 | 60 |
PH1042 | 42" | 10' | 5.1 | 2.5 / 2.5 | 1.8 / 1.6 | 0.8 | 0.7 | 66 | 60 |
PH1048 | 48" | 10' | 5.1 | 2.5 / 2.5 | 1.8 / 1.6 | 0.8 | 0.7 | 66 | 65 |
PH1060 | 60" | 10' | 10.2 | 5.0 / 5.0 | 3.6 / 3.2 | 1.6 | 1.4 | 68 | 100 |
PH1072 | 72" | 10' | 10.2 | 5.0 / 5.0 | 3.6 / 3.2 | 1.6 | 1.4 | 68 | 105 |
PH1084 | 84" | 10' | 10.2 | 5.0 / 5.0 | 3.6 / 3.2 | 1.6 | 1.4 | 68 | 125 |
PH1096 | 96" | 10' | 10.2 | 5.0 / 5.0 | 3.6 / 3.2 | 1.6 | 1.4 | 68 | 130 |
PH10108 | 108" | 10' | 15.3 | 7.5 / 7.5 | 5.4 / 4.8 | 2.4 | 2.1 | 71 | 170 |
PH10120 | 120" | 10' | 20.4 | 10.0 / 10.0 | 7.2 / 6.4 | 3.2 | 2.8 | 73 | 200 |
PH10144 | 144" | 10' | 20.4 | 10.0 / 10.0 | 7.2 / 6.4 | 3.2 | 2.8 | 73 | 210 |
DOOR SWITCHES
Automatic on/off control of air curtain as door is opened and closed
Line Voltage
- 99-014 Door Limit Switch - Combination roller and plunger • 20 amps, 250v, or 1 hp max.
24-Volt Control
- 99-018 Commercial Magnetic Reed Switch Only - Plastic • Surface-mounted • NOTE: Used with control packages for double doors
- 99-124 Industrial Floor-Mounted Magnetic Reed Switch Only - Floor-mounted • NOTE: Control panel required
- 99-125 Industrial Surface-Mounted Magnetic Reed Switch Only - Surface-mounted • NOTE: Control panel required
CONTROL PACKAGES
Combination packages of door switches, controllers, time delays, and thermostats
Line Voltage
- 99-063 Analog Thermostat - Remote-mounted
- 99-064 Analog Thermostat DPST - Double pole, single throw • Acts as heat on demand • Remote-mounted
24-Volt Control
- J0021 Commercial Magnetic Reed Switch with Controller and Adjustable - Time Delay • 115v 6 sec. – 20 min. • Plastic • Surface-mounted
- J0022 Commercial Magnetic Reed Switch with Adjustable Time Delay • 208-230v 1 6 sec. – 20 min. • Plastic • Surface-mounted
- J0023 Commercial Magnetic Reed Switch with Controller • 115v Plastic • Surface-mounted
- J0024 Commercial Magnetic Reed Switch with Controller • 208-230v 1? Plastic • Surface-mounted
- J0028 Door Limit Switch with Controller and Adjustable Time Delay • 115v 6 sec. – 20 min. • Surface-mounted
- J0029 Door Limit switch with Controller and Adjustable Time Delay • 208-230v 1F 6 sec. – 20 min. • Surface-mounted
- J0034 Door Limit Switch with Adjustable Time Delay 1 sec. – 17 min. • Surface-mounted • NOTE: Control panel required
- J0036 Industrial Magnetic Reed Switch with Controller • 115v Surface-mounted
- J0037 Industrial Magnetic Reed Switch with Controller • 208-230v 1 Surface-mounted
- J0038 Industrial Magnetic Reed Switch with Controller and Adjustable - Time Delay • 115v 6 sec. – 20 min. • Surface-mounted
- J0039 Industrial Magnetic Reed Switch with Adjustable Time Delay • 115v 1 sec. – 17 min. • Floor-mounted • NOTE: Control panel required
- J0040 Industrial Magnetic Reed Switch with Adjustable Time Delay 1 sec. – 17 min. • Surface-mounted • NOTE: Control panel required
- J0042 Industrial Magnetic Reed Switch with Controller and Adjustable Time Delay • 208-230v 1F 6 sec. – 20 min. • Surface-mounted
FILTERS
- STD2-FILTER-[size] - STD2 Aluminum Mesh Filter 1/4’ Internal-mount • Set of 2 • [size]: Specify size in inches
MOTOR CONTROL PANELS
Remote-mounted control panels for all 3F units and 1F units when greater than 1 hp (NEMA 1) • Units come
standard with HOA (hand/off/auto) switch • Panel shipped loose • Standard color Battleship Gray • NOTE: Electric
heated units include internal control panel and remote-mounted 24v thermostat with heat/off/fan only switch
[vc] Voltage codes: A = 115/1/60 D = 208-230/1/60 G = 208-230/3/60 H = 460/3/60 U = 220/1/50
- MCPA-1U 1-Motor Control Panel ½ hp • Unheated
- MCPA-2U 2-Motor Control Panel ½ hp • Unheated
- MCPA-3U 3-Motor Control Panel 1/2 hp • Unheated
- MCPA-4U 4-Motor Control Panel 1/2 hp • Unheated
- MCPA-5U 5-Motor Control Panel 1/2 hp • Unheated
- MCPA-6U 6-Motor Control Panel 1/2 hp • Unheated
- MCPA-1V 1-Motor Control Panel 1/2 hp • Steam/ Hot Water Heated
- MCPA-2V 2-Motor Control Panel 1/2 hp • Steam/ Hot Water Heated
- MCPA-3V 3-Motor Control Panel 1/2 hp • Steam/ Hot Water Heated
- MCPA-4V 4-Motor Control Panel 1/2 hp • Steam/ Hot Water Heated
- MCPA-5V Consult factory - 5-Motor Control Panel 1/2 hp • Steam/ Hot Water Heated
- MCPA-6V Consult factory - 6-Motor Control Panel 1/2 hp • Steam/ Hot Water Heated
PANEL ADD-ONs
- 94-013 Adjustable Time Delay 1 sec. - 17 min. • NOTE: Control panel required
- 99-165 Non-fused disconnect • 32 amps Panel-mounted
- 99-164 Non-fused disconnect • 63 amps Panel-mounted
- 99-114 Fused disconnect • 32 amps Panel-mounted
- 99-115 Fused disconnect • 63 amps Panel-mounted
- MCP-MTD Factory-Mounted Motor Control Panel
- HL2SPD 2-Speed Motor with Switch Off/Lo/Hi • Panel-mounted switch • NOTE: if 460v power is specified, a separate 115v or 208-230 1F service is required
- MSLAV Mater Slave Control with Single Thermostat
MULTI-SPEED CONTROL OPTIONS
- 99-003 3-Speed Remote switch • 25 amps Off/Lo/Med/Hi • Up to 1 hp 1F
- 99-033 2-Speed Remote Switch • 15 amps Off/Lo/Hi • Up to 1 hp 1F
- 99-034 2-Speed Remote Switch • 25 amps Off/Lo/Hi • Up to 1 hp 1F